[Linux-31] disk dur HS ?
Christophe
tx1138 at gmail.com
Jeu 5 Fév 16:04:55 CET 2015
Bonjour,
Je pense que le disk dur est hors service, selon les valeurs ci-dessous.
Ce qui m'embête le plus est de savoir si ce disk dur à reçu un choc !
Du fait de la valeur Free_Fall_Sensor qui est: 4
Pourrait-on afirmer qu'il y a eu choc ?
(Arghff 659 heures de vol l'engin seulement !!)
j'ai tenté d'installer un nouveau windows et j'ai un message d'erreur
(code erreur: 80800000)
Je copie le rapport complet ci-dessous
Merci pour vos retours
Christophe
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-23-generic] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 7200.4
Device Model: ST9500420AS
Serial Number: xxxxxxxxxxxx
LU WWN Device Id: 5 000c50 039046ec2
Firmware Version: D005SDM1
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Thu Feb 5 14:11:14 2015 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 121) The previous self-test completed
having
the read element of the test failed.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 108) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 095 078 006 Pre-fail
Always - 214247491
3 Spin_Up_Time 0x0003 100 099 085 Pre-fail
Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age
Always - 483
5 Reallocated_Sector_Ct 0x0033 054 054 036 Pre-fail
Always - 961
7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail
Always - 14803624
9 Power_On_Hours 0x0032 100 100 000 Old_age
Always - 659
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail
Always - 0
12 Power_Cycle_Count 0x0032 100 037 020 Old_age
Always - 471
184 End-to-End_Error 0x0032 100 100 099 Old_age
Always - 0
187 Reported_Uncorrect 0x0032 001 001 000 Old_age
Always - 24115
188 Command_Timeout 0x0032 100 098 000 Old_age
Always - 12885098502
189 High_Fly_Writes 0x003a 100 100 000 Old_age
Always - 0
190 Airflow_Temperature_Cel 0x0022 062 051 045 Old_age
Always - 38 (Min/Max 34/38)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age
Always - 20
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age
Always - 34
193 Load_Cycle_Count 0x0032 090 090 000 Old_age
Always - 20014
194 Temperature_Celsius 0x0022 038 049 000 Old_age
Always - 38 (0 6 0 0)
195 Hardware_ECC_Recovered 0x001a 053 042 000 Old_age
Always - 214247491
197 Current_Pending_Sector 0x0012 100 100 000 Old_age
Always - 40
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age
Offline - 40
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age
Always - 5
240 Head_Flying_Hours 0x0000 100 253 000 Old_age
Offline - 272979531399662
241 Total_LBAs_Written 0x0000 100 253 000 Old_age
Offline - 3923657144
242 Total_LBAs_Read 0x0000 100 253 000 Old_age
Offline - 1730549053
254 Free_Fall_Sensor 0x0032 001 001 000 Old_age
Always - 4
SMART Error Log Version: 1
ATA Error Count: 24147 (device log contains only the most recent five
errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 24147 occurred at disk power-on lifetime: 655 hours (27 days + 7
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 7c c6 ab 00 Error: UNC at LBA = 0x00abc67c = 11257468
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 3f c6 ab 40 00 01:18:18.130 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 01:18:18.068 IDENTIFY DEVICE
00 00 00 00 00 00 00 ff 01:18:17.944 NOP [Abort queued commands]
ec 00 00 00 00 00 00 00 01:18:17.881 IDENTIFY DEVICE
00 00 00 00 00 00 00 ff 01:18:17.757 NOP [Abort queued commands]
Error 24146 occurred at disk power-on lifetime: 655 hours (27 days + 7
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 7c c6 ab 00 Error: UNC at LBA = 0x00abc67c = 11257468
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 3f c6 ab 40 00 01:17:10.524 READ FPDMA QUEUED
60 00 08 6f c6 ab 40 00 01:17:09.937 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 01:17:09.875 IDENTIFY DEVICE
00 00 00 00 00 00 00 ff 01:17:09.751 NOP [Abort queued commands]
61 00 30 0f a1 5d 40 00 01:16:05.129 WRITE FPDMA QUEUED
Error 24145 occurred at disk power-on lifetime: 655 hours (27 days + 7
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 7c c6 ab 00 Error: UNC at LBA = 0x00abc67c = 11257468
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 3f c6 ab 40 00 01:16:02.144 READ FPDMA QUEUED
60 00 00 3f 7d 07 41 00 01:16:02.118 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 01:16:02.056 IDENTIFY DEVICE
00 00 00 00 00 00 00 ff 01:16:01.932 NOP [Abort queued commands]
ec 00 00 00 00 00 00 00 01:16:01.868 IDENTIFY DEVICE
Error 24144 occurred at disk power-on lifetime: 655 hours (27 days + 7
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 7c c6 ab 00 Error: UNC at LBA = 0x00abc67c = 11257468
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 00 3f c6 ab 40 00 01:14:54.157 READ FPDMA QUEUED
60 00 00 3f c4 72 40 00 01:14:54.155 READ FPDMA QUEUED
60 00 00 3f bd 3b 40 00 01:14:54.148 READ FPDMA QUEUED
60 00 00 3f b3 0e 40 00 01:14:54.135 READ FPDMA QUEUED
60 00 00 3f d4 0a 40 00 01:14:54.125 READ FPDMA QUEUED
Error 24143 occurred at disk power-on lifetime: 655 hours (27 days + 7
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 8f 63 ac 00 Error: UNC at LBA = 0x00ac638f = 11297679
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 80 7f 63 ac 40 00 01:04:54.206 READ FPDMA QUEUED
61 00 18 ff e7 5e 40 00 01:04:54.197 WRITE FPDMA QUEUED
61 00 00 9f 6f 51 41 00 01:04:54.194 WRITE FPDMA QUEUED
61 00 00 9f 6b 51 41 00 01:04:54.192 WRITE FPDMA QUEUED
61 00 08 4f e4 5b 40 00 01:04:54.163 WRITE FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining
LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: read failure 90%
657 11297679
# 2 Extended offline Completed: read failure 90%
657 11297679
# 3 Extended offline Completed: read failure 90%
656 11297679
# 4 Short offline Completed without error 00%
0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
--
Debian Lenny user 2.6.26/Xorg 7.0.2 & KDE 3.5.10
http://www.debian.org # http://fr.wikipedia.org/wiki/Obsolescence
https://soutien.laquadrature.net/
http://gnutux.free.fr # Il faut dire GNU/Linux :) # www.culte.org
--
GNU/Linux : May the Force be with you !
-------------- section suivante --------------
Une pièce jointe HTML a été nettoyée...
URL: <http://culte.org/pipermail/linux-31/attachments/20150205/7cd05f58/attachment.html>
Plus d'informations sur la liste de diffusion Linux-31